The Lambrecht ENGINEER
professional meteorological station is a complete meteorological equipment for the
most demanding professional observation. This meteorological station is specially indicated for professional observation,
research and exhaustive environmental control, in short: for
scientific use.
It incorporates the complete
set of sensors for observation, with the
Lambrecht quality guarantee and approval by the
World Meteorological Organization (WMO) . The sensors are made with the best materials on the market and guarantee
extraordinary durability and resistance . To complete the equipment, the Met [LOG] datalogger, the power [cube] power supply and the Met [app] are included for viewing and working with the recorded data.
Among the included sensors we highlight:
- TPH 8095 temperature, pressure and humidity sensor with sentry box, without ventilation.
- Static and ultrasonic u [sonic] anemometer capable of measuring streaks of up to 75m / s.
- Rocker rain gauge model 15189 according Joss-Tognini and Hellmann 200cm2, with 0.1mm resolution.
- 16106 pyranometer model for global radiation, with range 0 to 1400W / m2
With the
datalogger and the power cube as a supplementary energy source, the equipment is ready for use and installation. It also includes everything necessary for connection to the general 24VDC power supply.
Characteristics:
- Ultrasonic wind sensor u [sonic]
- Wind directi at Meas. range: 0 ... 359.9 ° · Accuracy: <2 ° (> 1 m / s) RMSE
- Wind speed Meas. range: 0 ... 75 m / s
- Accuracy: ± 0.2 m / s RMSE (v <10 m / s);
- ± 2% RMSE (10 m / s
- Precipitation at ECO sensor, 2 cm3 (15189)
- Meas. range: 0 ... 8 mm / min • Resolution on: 0.1 mm
- Accuracy: ± 2% with intensity correction at
- Temp./humidity/air pressure sensor THP (8095)
- Meas. range: -40 ... +70 ° C
- Accuracy: ± 0.3 ° C at (v> 2 m / s) •
- ± 0.4 ° C (10 ... 40 ° C) • ± 0.8 ° C (-10 ... 70 ° C)
- Relati sees humidity Meas. range: 0 ... 100% rh
- Accuracy: ± 3% (10 ... 90%) rh • ± 4% (0 ... 100%) rh
- Barometric pressure Meas. range: 500 ... 1100 hPa
- Accuracy: ± 2 hPa (-30 ... +70 ° C) • ± 1 hPa (-10 ... +60 ° C)
- Sensor shelter (8141.6)
- 11 lamellas, natural ventilation of the sensors
- Pyranometer (16106) Meas. range: 0 ... 1400 W / m2
- The data logger encountered [LOG]
- Ethernet: 10/100 BaseT • shielded RJ45 connector
- Interface: 3 x RS 485 (1 x freely configurable)
- Input: 4 analog / digital inputs (2 x freely configurable)
- 2 x Power Supply Power [cube]
- Power: every 150W
- Output: 24 VDC
- Tripod pole, height 2.5 m, made of aluminum, with mounting hardware